Exeltech XP125 125W Pure Sine Wave Inverter

EXELTECH Pure Sine Wave Inverters

XP 125

(PDF)

XP 125 Exeltech 125W Pure Sine Wave Inverter

Features Comments
  • True Sine Wave
  • 125 Watts AC Output
  • 12Vdc up to 108Vdc Output
  • Designed for Electronics
  • Ultra Lightweight
  • 21.5 Years MTBF
If you use a surge protection device to protect your electronic from the approximately 80 voltage spikes per day, received from the average electric company, don't trust those same electronics to the quasi sine wave power provided by most of the inverters on the market today. They deliver 120 voltage spikes per second, can cause equipment to malfunction, or be damaged, and in some cases, voids the warranty. Trust the accurate, efficient operation of your electronics to true sine wave inverters for 0 spike ANYTIME.

Model Number Description
XP1-1-1-6 125 Watt 12 VDC In 120 VAC / 60 Hz Output
XP1-1-2-6 125 Watt 24 VDC In 120 VAC / 60 Hz Output
XP1-1-4-6 125 Watt 48 VDC In 120 VAC / 60 Hz Output
XP1-3-1-5 125 Watt 12 VDC In 230 VAC / 50 Hz Output
XP1-3-2-5 125 Watt 24 VDC In 230 VAC / 50 Hz Output
XP1-3-4-5 125 Watt 48 VDC In 230 VAC / 50 Hz Output
XP1-1-1-4-1 125 Watt 12 VDC In 120 VAC /400 Hz Output
XP1-1-2-4-1 125 Watt 24 VDC In 120 VAC /400 Hz Output
XP1-1-4-4-1 125 Watt 48 VDC In 120 VAC /400 Hz Output
Other frequencies and voltages available

Output Power

Continuous Power Surge Power
No Load Power Output Voltage Output Current Weight (lbs)
125W 150W 5W 100 1.2 2
125W 150W 5W 117 1.1 2

Input Power

Model Voltage Minimum (Typical) System (Typical) Maximum (Typical) Typical Efficiency @ Full Power Peak Efficiency @ 1/3 Power
12V 10.4/10.6V* 13.8V 16.5V 85% 87%
24V 19/21V* 27.6V 33V 87% 89%
32V 26.5/28V* 36.8V 44V 87% 89%
48V 41.5/42.5V* 55.2V 62V 87% 89%
66V 57.5/58.5V 75.9V 91V 88% 90%
108V 94/95V 125V 149V 88% 90%
*Shutoff Voltage/Buzzer Voltage

General

Conditions Minimum Typical Maximum
Waveform - Sinusoidal -
Voltage Output -5% Nominal +5%
Line Regulation - 0.1% 0.5%
Load Regulation - 0.5% 1%
Distortion - 1.5% 2%
Frequency -0.1% Nominal +0.1%

Mechanical

Width Height Depth
4.65" 2.00" 6.75"

CAD Drawing
EXELTECH XP125 Mechanical Diagrams Pure Sine Wave Inverters

PROTECTION CIRCUITRY

*Over Voltage: Shut off at maximum input voltage, per input conditions.

*Under Voltage: Shut off at minimum input voltage, per input conditions. Warning buzzer sounds before shutoff.

*Thermal: 105ºC internal temperature. warning buzz 5ºC before shut off.

Output Short: Units shuts off and must be manually reset.

ENVIRONMENTAL

Temperature: -25 to 30ºC full power derated above 30ºC.

Humidity: 5 to 95% non condensing.

Altitude: -200 to 10k feet full power, derated above 10k.

Audible Noise: Less than 45dbA.

Cooling: Convection cooled.

Finish: Anodized aluminum.

Warranty: Full year parts and labor.

Extended Warranty: 5 year repair or replace unit for $50 per occurrence.


EXELTECH Pure Sine Wave Inverter Part Numbering System

Step 1: Model number always starts with XP.

Step 2: To designate wattage enter the single character code from the wattage chart below.

WATTAGE CHART

Wattage 125 250 600 1100
Designation 1 2 6 K

Step 3: To designate output voltage enter the single character code from the Vac chart.

Vac OUTPUT VOLTAGE CHART

AC Volts 100 120
Designation 0 1

Step 4: To Designate input voltage enter the single character code from the Vdc Chart.

Vdc INPUT VOLTAGE CHART

DC Volts 12 24 32 36 48 66 108
Designation 1 2 B 3 4 E I

Step 5: To designate AC frequency enter the single character code from the AC frequency chart.

AC FREQUENCY CHART

Frequency

50Hz

60Hz

400Hz

Designation

5

6

4



 