PROTECTION CIRCUITRY
*Over Voltage: Shut off at maximum input voltage, per input conditions.
*Under Voltage: Shut off at minimum input voltage, per input conditions. Warning buzzer sounds before shutoff.
*Thermal: 105C internal temperature. warning buzz 5 C before shut off.
Output Short: Units shuts off and must be manually reset. |
ENVIRONMENTAL
Temperature: -25 to 40 C full power derated above 40 C.
Humidity: 5 to 95% non condensing.
Altitude: -200 to 10k feet full power, derated above 10k.
Audible Noise: Less than 45 dbA
Cooling: Thermostatically controlled fan.
Finish: Painted aluminum.
Warranty: Full year parts and labor.
Extended Warranty: 5 year repair or replace unit for $100 per occurrence. |