| Electrical Characteristics |
Parameter |
Conditions |
APC-FP06 |
APC-FP10 |
Unit |
Min |
Typ |
Max |
Min |
Typ |
Max |
Operating Input Voltage |
|
85 |
|
264 |
170 |
|
264 |
Vrms |
Input surge limiting |
|
|
|
15 |
|
|
15 |
A |
Operating Input Current |
110 Vrms |
|
|
6.1 |
|
|
|
Arms |
230 Vrms |
|
|
2.9 |
|
|
4.6 |
Output voltage Setpoint |
230 Vrms, Full load |
372.4 |
380 |
387.6 |
372.4 |
380 |
387.6 |
V |
Output OVP Setpoint |
|
|
|
425 |
|
|
425 |
V |
Output current |
At 100°C baseplate temperature |
0 |
|
1.58 |
0 |
|
2.63 |
A |
Switching Frequency |
|
|
150 |
|
|
150 |
|
kHz |
Efficiency |
110V nominal input, 25°C base |
|
91 |
|
|
- |
|
% |
230V nominal input, base 25°C |
|
95 |
|
|
95 |
|
|
|
|
|
|
|
|
|
|
Undervoltage turn-on |
Increasing Input Voltage |
|
85 |
|
|
170 |
|
Vrms |
Undervoltage turn-off |
Decreasing Input Voltage |
|
81 |
|
|
162 |
|
Vrms |
Synchronization Frequency |
|
165 |
|
180 |
165 |
|
180 |
kHz |
|
|
|
|
|
|
|
|
|
Output Power |
APC-FP10 (max power de-rated at 6.7W/V from 200V input to 800W at 170 Vrms) |
|
|
|
0 |
|
1000 |
W |
APC-FP06 (max power de-rated at 6.7W/V from 100V input to 500W at 85 Vrms |
0 |
|
600 |
|
|
|
Line regulation & load regulation |
Low to high input voltage and 10% load to full load |
375 |
|
400 |
375 |
|
400 |
V |
Temperature regulation |
Deviation of output voltage from 25°C |
|
TBD |
|
|
TBD |
|
%/°C |
Ripple |
1000uF load capacitor |
|
|
10 |
|
|
10 |
V p-p |
Current limit |
|
|
|
2 |
|
|
3.3 |
A |
Short circuit current limit |
Crow bar short circuit |
|
TBA |
|
|
TBA |
|
A |
Enable Threshold |
Vout rising |
|
360 |
|
|
360 |
|
V |
Vout falling |
|
230 |
|
|
230 |
|
DC OK Threshold |
Vout rising |
|
360 |
|
|
360 |
|
V |
Vout falling |
|
350 |
|
|
350 |
|
Vaux output |
|
14 |
|
15 |
14 |
|
15 |
V |
Vaux current |
|
0 |
|
10 |
0 |
|
10 |
mA |
|
|
|
|
|
|
|
|
|
Length |
|
|
116.0 |
|
|
116.0 |
|
mm |
Width |
|
|
61 |
|
|
61 |
|
mm |
Height |
|
|
12.7 |
|
|
12.7 |
|
mm |
Thermal Resistance |
Base to heat sink, fitted with thermal pad |
|
0.1 |
|
|
0.1 |
|
°C/W |
Weight |
Approx |
|
170 |
|
|
170 |
|
gms |
|
|
|
|
|
|
|
|
|
Overtemperature shutdown |
|
100 |
105 |
110 |
100 |
105 |
110 |
°C |
Isolation voltage (in to base) |
Complies with basic insulation requirements |
1500 |
|
|
1500 |
|
|
Vrms |
Isolation voltage (out to base) |
Complies with basic insulation requirements |
1500 |
|
|
1500 |
|
|
Vrms |
Isolation capacitance |
Input to base |
|
TBA |
|
|
TBA |
|
pF |
Isolation resistance |
Input to base |
|
100M |
|
|
100M |
|
Ohms |
Agency approvals |
Nemko, CSA, US & Canada - Others per customer requirement |